Carbon Dioxide Monitor and Alarm - G01-CO2-B3 Series
Carbon Dioxide Monitor and Alarm - G01-CO2-B3 Series
◆ Real time carbon dioxide detection and monitoring◆ Temperature and humidity detection and display
◆ Three-color backlit LCD and buzzer alarm
◆ Provide 1xon/off output to control a ventilator
◆ Wall mounting and desktop placed
◆ High quality with the perfect appearance, CE-approval
- Model Number: G01-CO2-B3 Series
- Data Sheet:
- category: Instruments| Gas Detectors / Alarm / Monitor
Product Specification
Carbon Dioxide Monitor and AlarmModel: G01-CO2-B3Series
CO2+Temperature and Humidity Detection and Monitoring
◆ Real time carbon dioxide detection and monitoring
◆ Temperature and humidity detection and display
◆ Three-color backlit LCD and buzzer alarm
◆ Provide 1xon/off output to control a ventilator
◆ Wall mounting and desktop placed
◆ High quality with the perfect appearance, CE-approval
Features
◆ Design for real time monitoring room carbon dioxide level
◆ NDIR infrared CO2 sensor inside with special Self Calibration System. It makes the CO2 measurement more accurate and more reliable in use.
◆ More than 10 years lifetime of CO2 sensor
◆ Temperature and humidity monitoring
◆ Three-color (green/yellow/red) LCD backlit indicating ventilation optimal/moderate/poor based on the CO2 measurement
◆ Two alarm ways: buzzer alarm and backlight Colours switch
◆ Provide optional 1xrelay output to control a ventilator
◆ Easy touch button for operation
◆ High quality with the perfect appearance, best choice for home and office
◆ 220VAC or 24VAC/VDC power selectable; power adaptor available; desktop and wall mounting type available
◆ EU standard and CE-approval
Application
New G01-CO2 monitor/alarm is used to monitoring room CO 2 level, as well as room temperature and humidity. It provides one on/off output to control a ventilator with four CO2 levels presetting. Especially it provides both buzzer alarm and three colors backlit switching alarm.
◆ Hotel, exhibition hall, hospital, shop, restaurant, air port, train station, theater and other public places
◆ House, villa, office, meeting room, classroom and other rooms
◆ All ventilation systems
Specifications
Models Guide
2016年12月26日星期一
2016年12月16日星期五
15x15 SO2 Sensor 20 ppm P Package 110-601 - 3SP_SO2_20 P
3SP_SO2_20 P 15x15 SO2 Sensor 20 ppm P Package 110-601 - 3SP_SO2_20 P
• Small Size with Low Profile (20x20x4 mm)• Long Life (10 years expected life)
• Fast Response (< 15 seconds)
• Low Power Consumption
• Individually Calibrated (NIST Traceable)
• ROHS Compliant
- Model Number: 3SP_SO2_20 P
- Data Sheet:
- category: Sensors | Gas Sensor | Electrochemical Gas Sensors
Product Specification
3SP_SO2_20 P 15x15 SO2 Sensor 20 ppm P Package 110-601BENEFITS
• Small Size with Low Profile (20x20x4 mm)
• Long Life (10 years expected life)
• Fast Response (< 15 seconds)
• Low Power Consumption
• Individually Calibrated (NIST Traceable)
• ROHS Compliant
APPLICATIONS
• Air Quality Monitoring
• Industrial Safety
• Air Purification Control
DESCRIPTION
SPEC’s printed sensors offer the performance of the best quality electrochemical sensors at a fraction of the price. SPEC’s printed sensors are also ultra-thin, offering easy integration into wireless, portable, and networked solutions. These sensors are ideal for health, environmental, industrial and residential monitoring, because of their high performance, low cost and small size.
2016年12月13日星期二
2016年12月12日星期一
2016年12月8日星期四
2016年12月7日星期三
SO-A0-020 Limiting Current Type Sensor Oxygen Sensors
SO-A0-020 Limiting Current Type Sensor Oxygen Sensors
Measuring gas: Oxygen concentrationMeasuring medium: Gaseous atmosphere
Measuring principle: Limiting current type sensor
Measuring ranges: 0.01 – 2.0 vol.% O2
- Model Number: SO-A0-020
- Data Sheet:
- category: Sensors| Gas Sensors| Zirconium Dioxide Oxygen Sensors
Product Specification
SO-A0-020Limiting Current Type Sensor Oxygen Sensors
When voltage is applied to a zirconia electrolyte cell, oxygen is pumped through the zirconia disc from the cathode side to the anode side because the carriers of the current flowing through the zirconia electrolyte are oxygen ions. By attaching a cap with a pinhole on the cathode side of the cell and by increasing the voltage over the cell the current shows saturation due to the rate limiting step in the transfer of oxygen to the cathode. This saturation current is called limiting current and is nearly proportional to the ambient oxygen concentration.
Below the advantages of the oxygen sensor:
measuring range 0.01 to 2.0 vol.% oxygen
High accuracy
For many types a more or less linear characteristic
Small temperature dependence of the sensor signal
Low interference with other gases
Long service life
In many cases “Single point calibration“ necessary only once
Applications:
Medical
Laboratory
Food industry
Household/Gastronomy
Measuring technique
Security technology/Monitoring
(Electrical-) industry
Characteristic Data:
Measuring gas: Oxygen concentration
Measuring medium: Gaseous atmosphere
Measuring principle: Limiting current type sensor
Measuring ranges: 0.01 – 2.0 vol.% O2
Response time (t90): 2 to 25 sec. (Depends on: sensor type, gas flow, measuring chamber)
Sensor voltage / heating voltage / power consumption / heater cold resistance
Sensor voltage: 0.7 to 1.6 Volt
Heating voltage: 3.6 – 4.4 Volts
Power consumption: 1.3 to 1.8 Watts (depends on application and packaging)
Cold resistance: R( 25°C ) = 3.25Ω ± 0.20Ω
Warm up time: Min. 30 s
Maximum permissible operating temperature: 350°C (*)
*Depending on the cable and filter assembly (see paragraph: specification, Cable assembly)
Permissible volumetric flow rate (Purging the sensor)
For all sensor types, the maximum flow rate depends on the way of purging the sensor (sensor in direct gas flow, gas beam shape, etc.) and the size of the measuring chamber. Exception: SO-E1-xxx (TO8 + hose connection for direct gassing). Permissible flow
[ml/min]: 100 - 500 (optimal: 250)
Lifetime (MTTF): ~ 20.000 hours (*)
*Depending on measuring medium. Stated lifetime refers to a heated, operated sensor of type SO-xx-250 and SO-xx-960. A failure or reaching the lifetime typically means a slight deviation from the dispatch specifications.
Vibration resistance
Sensors based on the TO8 socket as well as those built with a TO39 socket (SO-Bx-xxx, SO-Ex-xxx, SO-Ax-xxx) meet the European Norm EN60068-2-6 (Sinusoidal vibration tests).