CO-A4 Carbon Monoxide Sensor 4-Electrode
Temperature range :-30 to 50 ℃Pressure range : 80 to 120 kPa
Humidity range :15 to 90 % rh continuous
Storage period : 6 months @ 3 to 20 ℃ (stored in sealed pot)
Load resistor :33 to 100 Ω (AFE circuit is recommended)
Weight : < 6g
- Model Number: CO-A4
- Data Sheet:
- category: Sensors | Gas Sensors | Electrochemical Sensors
Product Specification
CO-A4 Carbon Monoxide Sensor 4-ElectrodePERFORMANCE
Sensitivity nA/ppm in 2ppm CO 220 to 375
Response time t90 (s) from zero to 10ppm CO < 20
Zero current nA in zero air at 20℃ -100 to +10
Noise* ±2 standard deviations (ppb equivalent) 20
Range ppm limit of performance warranty 500
Linearity ppm CO error at full scale, linear at zero, 15ppm CO < ± 1
Overgas limit maximum ppm for stable response to gas pulse 2000
* Tested with Alphasense AFE low noise circuit
LIFETIME
Zero drift ppb equivalent change/year in lab air < ±100
Sensitivity drift % change/year in lab air, monthly test < 10
Operating life months until 50% original signal (24 month warranted) > 36
ENVIRONMENTAL
Sensitivity @ -20℃ (% output @ -20℃/output @ 20℃) @ 5ppm CO 50 to 85
Sensitivity @ 50℃ (% output @ 50℃/output @ 20℃) @ 5ppm CO 110 to 125
Zero @ -20℃ nA change from 20℃ 10 to 40
Zero @ 50℃ nA change from 20℃ -120 to -200
CROSS SENSITIVITY
Filter capacity ppm·hrs H2S 250,000
H2S sensitivity % measured gas @ 5ppm H2S < 0.1
NO2 sensitivity % measured gas @ 5ppm NO2 < -2
Cl2 sensitivity % measured gas @ 5ppm Cl2 < 0.1
NO sensitivity % measured gas @ 5ppm NO < -2
SO2 sensitivity % measured gas @ 5ppm SO2 < 0.1
H2 sensitivity % measured gas @ 100ppm H2 at 20℃ < 10
C2H4 sensitivity % measured gas @ 100ppm C2H4 < 0.5
NH3 sensitivity % measured gas @ 20ppm NH3 < 0.1
KEY SPECIFICATIONS
Temperature range ℃ -30 to 50
Pressure range kPa 80 to 120
Humidity range % rh continuous 15 to 90
Storage period months @ 3 to 20 ℃ (stored in sealed pot) 6
Load resistor Ω (AFE circuit is recommended) 33 to 100
Weight g < 6
没有评论: