NTM SenseH2 Hydrogen Sensor - SenseH2
High sensitivity and selectivity to hydrogenFast response and recovery times
Immune to signal saturation
Robust to widely varying ambient flow rates
Compact and rugged design
1.0 to 4.5V output, spans 0.25 to 4.0% H2 in air(5 to 100% LFL)
UL Classified, ATEX, CE for hazardous locations
- Model Number: SenseH2
- Data Sheet:
- catogery: Gas Sensors | Electrochemical Gas Sensors
Product Specification
Overview
Designed for hydrogen monitoring, this ceramic sensor exhibits a highly sensitive, selective, and rapid response to thepresence of hydrogen in ambient air. It reliably measures H2 concentrations over a wide range of temperature and
humidity variation and provides a repeatable response, even in the presence of other combustible gases. Additionally,
the NTM SenseH2® hydrogen sensor is immune to signal saturation upon continuous exposure to low levels of hydrogen,
and recovers rapidly and completely upon hydrogen removal.
System Components
Sensor: The sensor element employs a patent‐pending, chemi‐resistive ceramic technology, which provides accurateand reliable hydrogen detection.
Features
High sensitivity and selectivity to hydrogenFast response and recovery times
Immune to signal saturation
Robust to widely varying ambient flow rates
Compact and rugged design
1.0 to 4.5V output, spans 0.25 to 4.0% H2 in air(5 to 100% LFL)
UL Classified, ATEX, CE for hazardous locations
Table of Typical Characteristics
Metric | Min | Max | Units |
Characteristics: | |||
H2 range (in air) | 0.25 | 4 | % |
Voltage input | 12 | 24 | Vdc |
Output (sensing range) | 1 | 4.5 | Vdc |
Error state (output signal) | 0.5 | 0.5 | Vdc |
Error state (output signal) | 4.75 | 4.75 | Vdc |
Power consumption (25°C) | 0.1 | 0.15 | A |
Response time (T90) | — | 5 | Sec. |
Recovery time (T10) | — | 5 | Sec. |
Environmental Conditions: | |||
Ambient temperature | ‐20 | 80 | °C |
Relative humidity | 5 | 95 | %R.H. |
Linear flow rate | 0.02 | 5 | m/s |