NTM SenseH2 Hydrogen Sensor

Product Specification

Overview

Designed for hydrogen monitoring, this ceramic sensor exhibits a highly sensitive, selective, and rapid response to the
presence of hydrogen in ambient air. It reliably measures H2 concentrations over a wide range of temperature and
humidity variation and provides a repeatable response, even in the presence of other combustible gases. Additionally,
the NTM SenseH2® hydrogen sensor is immune to signal saturation upon continuous exposure to low levels of hydrogen,
and recovers rapidly and completely upon hydrogen removal.

System Components

Sensor: The sensor element employs a patent‐pending, chemi‐resistive ceramic technology, which provides accurate
and reliable hydrogen detection.


Features

High sensitivity and selectivity to hydrogen
Fast response and recovery times
Immune to signal saturation
Robust to widely varying ambient flow rates
Compact and rugged design
1.0 to 4.5V output, spans 0.25 to 4.0% H2 in air(5 to 100% LFL)
UL Classified, ATEX, CE for hazardous locations

Table of Typical Characteristics

Metric Min Max Units
Characteristics:
H2 range (in air) 0.25 4 %
Voltage input 12 24 Vdc
Output (sensing range) 1 4.5 Vdc
Error state (output signal) 0.5 0.5 Vdc
Error state (output signal) 4.75 4.75 Vdc
Power consumption (25°C) 0.1 0.15 A
Response time (T90) 5 Sec.
Recovery time (T10) 5 Sec.
Environmental Conditions:
Ambient temperature ‐20 80 °C
Relative humidity 5 95 %R.H.
Linear flow rate 0.02 5 m/s